What are the safety protection norms for refrigeration system in cold storage?
2024-08-28
There are many factors affecting the cost of cold storage construction, such as the size of the cold storage, the selection of the refrigeration system of the cold storage, the insulation materials of the cold storage, etc.
First, pressure safety protection in the safety protection specifications of the cold storage refrigeration system. In order to prevent the refrigeration system from operating under overpressure, safety valves, pressure relays or differential pressure relays and automatic alarm lights and other pressure protection safety equipment are installed on the refrigeration equipment. In case of overpressure operation, the safety equipment will act automatically to discharge part of the gas in the system to the atmosphere or shut down automatically to ensure the safety of equipment and personnel.
Second, liquid level safety protection in the safety protection specifications of the cold storage refrigeration system. To prevent safety problems caused by excessive liquid level in equipment such as gas-liquid separators and intermediate coolers or operational failures caused by too low liquid level, float ball liquid level controllers or commonly used liquid level automatic control devices for refrigeration equipment are usually used to automatically control the liquid level of these devices.
Third, temperature safety protection in the safety protection specifications of the cold storage refrigeration system.
Other safety protection specifications for the cold storage refrigeration system, such as setting up an emergency ammonia discharge valve in the ammonia refrigeration system, installing a check valve on a screw compressor to prevent the refrigerant from flowing back, and setting up an emergency shutdown device in the refrigeration system.
First, pressure safety protection in the safety protection specifications of the cold storage refrigeration system. In order to prevent the refrigeration system from operating under overpressure, safety valves, pressure relays or differential pressure relays and automatic alarm lights and other pressure protection safety equipment are installed on the refrigeration equipment. In case of overpressure operation, the safety equipment will act automatically to discharge part of the gas in the system to the atmosphere or shut down automatically to ensure the safety of equipment and personnel.
Second, liquid level safety protection in the safety protection specifications of the cold storage refrigeration system. To prevent safety problems caused by excessive liquid level in equipment such as gas-liquid separators and intermediate coolers or operational failures caused by too low liquid level, float ball liquid level controllers or commonly used liquid level automatic control devices for refrigeration equipment are usually used to automatically control the liquid level of these devices.
Third, temperature safety protection in the safety protection specifications of the cold storage refrigeration system.
Other safety protection specifications for the cold storage refrigeration system, such as setting up an emergency ammonia discharge valve in the ammonia refrigeration system, installing a check valve on a screw compressor to prevent the refrigerant from flowing back, and setting up an emergency shutdown device in the refrigeration system.
Related Articles
- What safety measures should be paid attention to during the installation of cold storage?
- Analysis of Causes for Safety Valve Leakage
- Scheme for the Use and Safety of Ammonia Refrigerants
- Safety Regulations for Ammonia Refrigeration Machine Room
- Safety Protection in Refrigeration Devices
- How Food Cold Storages Ensure Food Safety
- Common Pressure Valves and Protection Devices in Refrigeration Units
- How to Troubleshoot and Repair High - pressure Protection of Air - cooled Units?
- Practical Knowledge on Freeze Protection of Air - conditioning Equipment
- Common Causes and Analysis of Compressor Thermal Protection
- Introduction to Vapor Barrier of Cold Storage and Moisture Protection of Equipment
- Cold Storage Protection: Odor Removal and Maintenance Methods
- 15 Common Protections of Refrigeration Equipment
- Have You Encountered the Three Common Problems of Refrigeration Compressors?
- How to Calculate Refrigeration Load? And What Are the Issues?
- What to Do if the Compressor of a Frozen and Refrigerated Display Cabinet Runs but the Refrigeration Effect Is Poor?
- Instructions for Welding and Drainage in the Installation of Refrigeration Equipment Pipelines
- Precautions for Using Rotary Refrigeration Compressors